Bone Collector and GBR Fixation Kits

Dental Implant GBR Bone Tack Kits
GBR bone tack kits with titanium tacks in 2.5 and 3.5 mm and a stainless steel placement handle, for holding a membrane firmly over a bone graft during guided bone regeneration.

Four-Drill Bone Collector Set with Metal Holder
Four bone collector drills marked 3.4, 4.0, 4.2 and 5.2 mm, with slotted heads that gather the patient’s own bone while drilling. Supplied in a metal holder with a hinged lid.
Bone Collector and GBR Fixation Kits Selection Summary
| Specification | Details |
|---|---|
| Bone collector set | Four collector drills marked 3.4, 4.0, 4.2 and 5.2 mm, one of each; slotted gold-coloured heads; metal holder with hinged lid and four labelled positions, not counted among the four drills |
| GBR bone tack kits | Titanium tacks in 2.5 and 3.5 mm; stainless steel placement handle; circular tack holder |
| GBR kit options | Titanium bone tack set; guided bone tack and pin kit (titanium pins with a guide); expanded membrane-fixation kit |
| Not included | Membranes and graft material |
| Order unit | Collector set: one four-drill set with holder. Tack kits: one kit by option; replacement tacks quoted by kit and tack size |
| Matching fields | Tack diameter and length, head dimensions, placement-handle reference and guide fit; collector shank or handpiece fit |
Other Dental Implant Instruments Subcategories
Implant Drill Kits
An eight-drill surgical kit (2.0 to 5.2 mm, depth-marked) and conical drill and stopper kits in 25 to 55 pieces. Compare drills, s...
View SubcategoryGuided Implant Surgery Kits
Implant positioning kits with a 2.0 mm pilot drill and guides from 6.0 to 12.0 mm, plus a 15-piece option with 4 and 4.5 mm tissue...
View SubcategoryBone Expansion & Osteotome Kits
Screw-type bone expander kits (2.6–4.3 mm), a five-piece offset concave osteotome set (2.8–4.8 mm) and a nine-piece chisel and mal...
View SubcategoryImplant Prosthetic Instruments
A three-piece collet-style holder that grips an implant abutment outside the mouth while it is shaped in the laboratory. Not a dri...
View SubcategoryBone Collector and GBR Fixation Kits FAQ
Is the metal holder one of the four collector drills?
No. The set is four bone collector drills, marked 3.4, 4.0, 4.2 and 5.2 mm, one of each, plus a metal holder with a hinged lid and four labelled positions. The holder is a separate object in the box, so the set is four drills and one holder, not five drills.
How do bone collection, graft delivery and membrane fixation instruments differ?
These are separate instrument functions within the grafting range. A collector or scraper belongs to collection, a delivery instrument has its own material-handling configuration, and a tack or screw system has a matching fixation interface. Keep the required function and component references explicit rather than treating a GBR-kit title as a complete inventory.
Do the 3.4 to 5.2 mm markings give the inside or outside diameter of a collector drill?
They are nominal size markings and do not say whether the figure is an inside or an outside diameter, nor do they state the usable length or the shank. If the bore or a handpiece fit matters for your work, ask before you order and tell us the handpiece or system you plan to use.
Does a grafting-instrument kit include graft material or membranes?
Not unless the offer says so. List instruments, graft material and membranes as separate purchasing requirements unless the selected offer itemizes them together. A grafting or GBR instrument title identifies the tool range, not the supplied biomaterial or membrane, so keep each consumable's reference and quantity apart from the reusable-instrument schedule.
Are the tacks and the placement handle the same component?
No. In the tack set the titanium tacks and the stainless steel placement handle are separate components, kept in a circular holder; the handle picks up each tack and presses it into place. Order them as separate lines, name the kit and tack size for replacement tacks, and keep the handle's processing instructions apart from the tacks' supply instructions.
What establishes a match between a membrane tack and its placement handle?
Use the documented tack and placement-handle pairing or their exact matched system references. A similar tack head, generic diameter or handle appearance does not establish the interface. Preserve that pairing when ordering replenishment, and distinguish membrane-fixation components from components used to retain a surgical guide.
How should tack dimensions be recorded on a purchasing list?
Keep diameter and length in separate fields and identify their measurement locations from the exact specification or drawing. Head diameter, shaft diameter and overall length describe different features. A pair of unexplained numbers should remain with its source reference until their meaning is defined, rather than being assigned assumed axes.
How should a tack-kit refill be compared with a complete kit?
Compare tack reference, size allocation and quantity, then separately list the matched handle, holder and case. A refill and a complete kit can have different contents even when shown with similar storage. Use the selected offer schedule rather than empty holder positions, filenames or a total title count to establish what is supplied.
Is the guided bone tack and pin kit a guided implant surgery system?
No. The guide in that option belongs to the titanium pins used for membrane fixation. It is different from the drilling guides and sleeves in guided implant surgery kits, which are a separate collection with their own drill and sleeve references.
Need Bone Grafting & GBR Kits in Bulk?
Send your instrument list and quantities for manufacturer-direct pricing, custom branding, or mixed-category quotes.
