Bone Collector and GBR Fixation Kits Products

2 products
GBR tack placement instrument and circular tack holder — view 1

Dental Implant GBR Bone Tack Kits

GBR bone tack kits with titanium tacks in 2.5 and 3.5 mm and a stainless steel placement handle, for holding a membrane firmly over a bone graft during guided bone regeneration.

Stainless steel; component-specific material confirmed with the quotation
3 variations available
Four bone collector drills in a holder marked 3.4, 4.0, 4.2 and 5.2 mm

Four-Drill Bone Collector Set with Metal Holder

Four bone collector drills marked 3.4, 4.0, 4.2 and 5.2 mm, with slotted heads that gather the patient’s own bone while drilling. Supplied in a metal holder with a hinged lid.

Bone Collector and GBR Fixation Kits Selection Summary

SpecificationDetails
Bone collector setFour collector drills marked 3.4, 4.0, 4.2 and 5.2 mm, one of each; slotted gold-coloured heads; metal holder with hinged lid and four labelled positions, not counted among the four drills
GBR bone tack kitsTitanium tacks in 2.5 and 3.5 mm; stainless steel placement handle; circular tack holder
GBR kit optionsTitanium bone tack set; guided bone tack and pin kit (titanium pins with a guide); expanded membrane-fixation kit
Not includedMembranes and graft material
Order unitCollector set: one four-drill set with holder. Tack kits: one kit by option; replacement tacks quoted by kit and tack size
Matching fieldsTack diameter and length, head dimensions, placement-handle reference and guide fit; collector shank or handpiece fit

How to Compare Bone Collector and GBR Fixation Kits

Collect Bone or Fix the Membrane: Two Different Jobs

A bone collector drill gathers the bone chips it cuts instead of letting them wash away. The slotted head traps the chips as it drills, and they can then be used as graft material from the patient's own bone. Membrane fixation is a separate job: in guided bone regeneration a membrane covers a bone graft, and small titanium tacks pin it to the bone so it cannot shift, using a handle that picks up each tack and presses it into place.

The two listings do not share components, so order each on its own line with its own size references.

The Four-Drill Collector Set: Four Drills and One Holder

The set has four bone collector drills, one each marked 3.4, 4.0, 4.2 and 5.2 mm, with slotted, gold-coloured heads. They are supplied in a metal holder with a hinged lid and four labelled positions. The holder is an extra object in the box, not a fifth drill, so count four drills and one holder. The sizes are nominal markings: they do not say whether the figure is an inside or an outside diameter, so if that distinction matters to your work, ask before you order.

If you plan to use the drills with a particular handpiece or implant system, tell us and we confirm the shank fits before you order. Collector drills are one of three ways to gather bone: a hand-held curved bone scraper shaves it from the surface, and a bone mill grinds removed bone into particles.

GBR Bone Tack Kits: Compare the Three Options

Every GBR kit is built around titanium bone tacks in 2.5 and 3.5 mm, a stainless steel placement handle and a circular holder that keeps the tacks organised and ready to pick up. The titanium bone tack set is the tacks and the placement handle. The guided bone tack and pin kit is titanium pins with a guide. The expanded membrane-fixation kit is a larger kit with more fixation instruments. We send an itemised list for the option you choose, and the number of tacks of each size is confirmed in your quotation.

The tacks and the handle are separate components, so give the tack diameter and length, the head dimensions, the placement-handle reference and any guide interface when you order replacements. Replacement tacks can be quoted by naming the kit and the tack size. Membranes and graft material are not included, so list them separately if you need them.

Keep PRF Handling and Graft Delivery Separate

PRF boxes and handling sets are a related but different equipment family. The PRF process kit lists seven hand instruments, a PRF box, a 12-position tube stand, a 60 mm bowl and a cassette; the gold-cassette kit holds the same seven instruments in a gold-finish cassette and has no PRF box. A centrifuge and blood-collection tubes are not included in any PRF option. Delivering collected graft material to the site is another job, handled by the curved bone graft syringe set, which does not include graft material.

Make Replenishment Traceable to the Original Set

When you ask for replacement collector drills, tacks or placement handles, identify the kit or option, the component, its nominal size and, where you have one, a drawing or sample. Add the quantity, destination and any container or documentation requirement.

Keep the itemised list that came with your quotation. It lets a repeat purchase match the set you received rather than rely on an assumed accessory count, and it keeps the reusable instruments, with their processing instructions, apart from the tacks, with their supply instructions.

Bone Collector and GBR Fixation Kits FAQ

Is the metal holder one of the four collector drills?

No. The set is four bone collector drills, marked 3.4, 4.0, 4.2 and 5.2 mm, one of each, plus a metal holder with a hinged lid and four labelled positions. The holder is a separate object in the box, so the set is four drills and one holder, not five drills.

How do bone collection, graft delivery and membrane fixation instruments differ?

These are separate instrument functions within the grafting range. A collector or scraper belongs to collection, a delivery instrument has its own material-handling configuration, and a tack or screw system has a matching fixation interface. Keep the required function and component references explicit rather than treating a GBR-kit title as a complete inventory.

Do the 3.4 to 5.2 mm markings give the inside or outside diameter of a collector drill?

They are nominal size markings and do not say whether the figure is an inside or an outside diameter, nor do they state the usable length or the shank. If the bore or a handpiece fit matters for your work, ask before you order and tell us the handpiece or system you plan to use.

Does a grafting-instrument kit include graft material or membranes?

Not unless the offer says so. List instruments, graft material and membranes as separate purchasing requirements unless the selected offer itemizes them together. A grafting or GBR instrument title identifies the tool range, not the supplied biomaterial or membrane, so keep each consumable's reference and quantity apart from the reusable-instrument schedule.

Are the tacks and the placement handle the same component?

No. In the tack set the titanium tacks and the stainless steel placement handle are separate components, kept in a circular holder; the handle picks up each tack and presses it into place. Order them as separate lines, name the kit and tack size for replacement tacks, and keep the handle's processing instructions apart from the tacks' supply instructions.

What establishes a match between a membrane tack and its placement handle?

Use the documented tack and placement-handle pairing or their exact matched system references. A similar tack head, generic diameter or handle appearance does not establish the interface. Preserve that pairing when ordering replenishment, and distinguish membrane-fixation components from components used to retain a surgical guide.

How should tack dimensions be recorded on a purchasing list?

Keep diameter and length in separate fields and identify their measurement locations from the exact specification or drawing. Head diameter, shaft diameter and overall length describe different features. A pair of unexplained numbers should remain with its source reference until their meaning is defined, rather than being assigned assumed axes.

How should a tack-kit refill be compared with a complete kit?

Compare tack reference, size allocation and quantity, then separately list the matched handle, holder and case. A refill and a complete kit can have different contents even when shown with similar storage. Use the selected offer schedule rather than empty holder positions, filenames or a total title count to establish what is supplied.

Is the guided bone tack and pin kit a guided implant surgery system?

No. The guide in that option belongs to the titanium pins used for membrane fixation. It is different from the drilling guides and sleeves in guided implant surgery kits, which are a separate collection with their own drill and sleeve references.

Need Bone Grafting & GBR Kits in Bulk?

Send your instrument list and quantities for manufacturer-direct pricing, custom branding, or mixed-category quotes.

WhatsApp